Home > Á¦Ç°¼Ò°³ > ´ëÀü·ÂÇü ±Ç¼±ÀúÇ×±â
ÀúÇ×±âÀÇ ±¸Á¶´Â Àý¿¬°­µµ³»¾ÐÀÌ ÁÁÀº Àý¿¬Ã¼ À§¿¡
ÀúÇ×¼±À» °¨ÀºÈÄ ºÒ¿¬¼º µµ·á·Î µµÆ÷ÇÏ¿© ³»¿­¼ºÀÌ
¿ì¼öÇϹǷΠ°íÀü·ÂÀÌ ¿ä±¸µÇ´Â »ê¾÷¿ë±â±â¿¡ ÀûÇÕ
ÇÕ´Ï´Ù.

RWH type resistor is optimum for industrial and high-power
instruments from 20w to 2kw.
The structure of RWH type resistor is that nickel-chrome
wire is wound on aninsulator that has good insulation,
strenght and withstanding voltage and, it is coverd with
glaze.



 
Temperature Coefficient ¡¾200ppm/¡ÆC max
Power Rating Load ¡¾[1% + 0.05§Ù] [JIS-C-5202, 5-4] 350¡ÆC max
Short Time Overload ¡¾[2% + 0.05§Ù] 1000% rated power 5 secs
Insulation Resistance 100M§Ù min. DC 500V
Dielectric Withstanding Voltage RWA : AC 1500V 1 minutes, RWH : AC 3000V 1 minutes
Terminal Strength 5~20W : 4.5kgf, H20~40W : 6kgf, 60~200W:8kgf, 300~400W : 10kgf-30secs
Resistors Strength 5~40W:20kgf, 60~400W:30kgf-30secs
Vibration Mount : RWH 1.5mm 10~55Hz/1min. X,Y,Z 2 hours each direction
Solderability 75% coverage MIN 270¡ÆC 5 secs
Heat Resistance 350¡ÆC 2 hours
Thermal Shock ¡¾[2% + 0.05§Ù] Power rating load 30min., -55¡ÆC 15min
Humidity (Steady state) ¡¾[2% + 0.05§Ù] ,
10M§Ù MIN.
40¡ÆC, 95%RH, DC100V 500 hours
Moisture Load Life ¡¾[2% + 0.05§Ù] 0.1xpower rating, 90min. on, 30min off, 40¡ÆC, 95% RH, 500 hours
Load Life ¡¾[5% + 0.05§Ù] Power rating,, 90 min. on, 30 min off, 500 hours
Flame Retardant no evidence of
flaming or arcing
100~600% rated power load
Type Rated
Wattage
Dimensions [mm]
A B C D E F I J K L M N P Q O T
RWH
RWD
RWA

15

17 50 20 8.5 5 2.8 4.2 18 22 41 71 86 26 3.5 6 0.5
20 17 50 20 8.5 5 2.8 4.2 18 22 41 71 86 26 3.5 6 0.5
30 17 75 20 8.5 5 2.8 4.2 18 22 41 99 110 26 3.5 6 0.5
40 17 90 20 8.5 5 2.8 4.2 18 22 41 115 124 26 3.5 6 0.5
50 28 75 33 14 8 4 6 26 30 62 110 133 35 4.2 8.5 1.4
60 28 90 33 14 8 4 6 26 30 62 128 148 35 4.2 8.5 1.4
80 28 115 33 14 8 4 6 26 30 62 150 173 35 4.2 8.5 1.4
100 28 140 33 14 8 4 6 26 30 62 175 198 35 4.2 8.5 1.4
120 28 165 33 14 8 4 6 26 30 62 200 221 35 4.2 8.5 1.4
150 28 195 33 14 8 4 6 26 30 62 230 253 35 4.2 8.5 1.4
200 28 254 33 14 8 4 6 26 30 62 390 313 35 4.2 8.5 1.4
300 42 254 45 24 12 5.5 6.5 40 40 86 300 330 52 5 12 1.6
400 42 330 45 24 12 5.5 6.5 40 40 86 380 407 52 5 12 1.6
500 52 330 57 29 15 9 6.5 54 41 99 345 362 53 5 12 2.2
600 52 330 57 29 15 9 6.5 54 41 99 375 392 53 5 12 2.2
800 65 330 65 46 20 10 10 65 59 126 385 404 72 10 20 2.2
1000 77 330 71 47 20 10 10 75 63 130 388 408 80 10 20 2.2
1200 77 330 71 47 20 10 10 75 63 130 388 408 80 10 20 2.2
1500 77 420 71 47 20 10 10 75 63 130 478 498 80 10 20 2.2
2000 77 500 71 47 20 10 10 75 63 130 558 578 80 10 20 2.2


When Loading for a short time with a cycle of over 30 minutes, the load can be more than the rated power. To avoid short circuits between cables, do not exceed the maximum capable voltage between terminals.